Omfattning
This Part of EN 1366 specifies a method of test and criteria for the evaluation (including field of application rules) of the ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service. Penetration seals used to seal gaps around chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke extraction ducts are excluded from this standard except for mixed penetration seals. The fire resistance of those services itself cannot be assessed with the methods described in this standard. Supporting constructions are used in this standard to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice. This European Standard is used in conjunction with EN1363-1. The purpose of this test described in this standard is to assess: a) the effect of such penetrations on the integrity and insulation performance of the separating element concerned; b) the integrity and insulation performance of the penetration seal; c) the insulation performance of the penetrating service or services, and where necessary, the integrity failure of a service. No information can be implied by the test concerning the influence of the inclusion of such penetrations and sealing systems on the loadbearing capacity of the separating element. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena are only to be noted in describing the general behaviour of test specimens during the test.

Ämnesområden

Brandtålighet för byggnadsmaterial (13.220.50)


Köp denna standard

Standard Svensk standard · SS-EN 1366-3:2009

Provning av brandmotstånd för installationer i byggnader - Del 3: Tätning av genomföringar
Prenumerera på standarden - Läs mer Dölj
Pris: 1 731 SEK
standard ikon pdf

PDF

Pris: 1 731 SEK
standard ikon

Papper

Pris: 2 769,60 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Brandsäkerhet, SIS/TK 181

Internationell titel: Fire resistance tests for service installations - Part 3: Penetration seals

Artikelnummer: STD-69042

Utgåva: 2

Fastställd: 2009-03-09

Antal sidor: 116

Ersätter: SIS 24820 , SS-EN 1366-3:2005

Ersätts av: SS-EN 1366-3:2022