Standard ISO standard · ISO 22441:2022

Sterilization of health care products — Low temperature vaporized hydrogen peroxide — Requirements for the development, validation and routine control of a sterilization process for medical devices

Status: Gällande

Köp denna standard

Standard ISO standard · ISO 22441:2022

Sterilization of health care products — Low temperature vaporized hydrogen peroxide — Requirements for the development, validation and routine control of a sterilization process for medical devices
Prenumerera på standarden - Läs mer Dölj
Pris: 2 614 SEK
standard ikon pdf

PDF

Pris: 2 614 SEK
standard ikon

Papper

Fler alternativ Färre alternativ
Provläs denna standard
Omfattning
1.1  Inclusions


1.1.1    This document provides requirements for the development, validation and routine monitoring and control of a low temperature sterilization process for medical devices using vaporized hydrogen peroxide (VH2O2) as the sterilizing agent.


1.1.2    This document is intended to be applied by process developers, manufacturers of sterilization equipment, manufacturers of medical devices to be sterilized, organizations performing process validation of VH2O2 sterilization, and organizations responsible for sterilizing medical devices.


NOTE      VH2O2 sterilizers can be used in both health care and industrial facilities, and this document acknowledges the similarities and differences between the two applications.


1.2  Exclusions


1.2.1    Processes that use other sterilizing agents, or hydrogen peroxide solution in combination with other chemicals as the sterilizing agent are not addressed in this document.


NOTE      See ISO 14937 for guidance on validation of such processes.


1.2.2    This document does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies, e.g. scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents.


NOTE      Some VH2O2 sterilizers have processes that demonstrate some level of inactivation of the causative agents of spongiform encephalopathies, e.g. scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob Disease. However, this inactivation is process, cycle, and test protocol specific, therefore this inactivation is outside the scope of this document, and no specific test methods are provided (see [14], [26], and [30] for more information).


1.2.3    This document does not specify requirements for designa...

Ämnesområden

Sterilisering och desinficering allmänt (11.080.01)


Köp denna standard

Standard ISO standard · ISO 22441:2022

Sterilization of health care products — Low temperature vaporized hydrogen peroxide — Requirements for the development, validation and routine control of a sterilization process for medical devices
Prenumerera på standarden - Läs mer Dölj
Pris: 2 614 SEK
standard ikon pdf

PDF

Pris: 2 614 SEK
standard ikon

Papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: ISO

Internationell titel: Sterilization of health care products — Low temperature vaporized hydrogen peroxide — Requirements for the development, validation and routine control of a sterilization process for medical devices

Artikelnummer: STD-80037556

Utgåva: 1

Fastställd: 2022-08-26

Antal sidor: 79