Standard Swedish standard · SS-EN ISO 80601-2-74:2020

Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment (ISO 80601-2-74:2017)

Status: Withdrawn

· Replaced by: SS-EN ISO 80601-2-74:2021
Buy this standard

Standard Swedish standard · SS-EN ISO 80601-2-74:2020

Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment (ISO 80601-2-74:2017)
Subscribe on standards - Read more Dölj
Price: 1 731 SEK
standard ikon pdf

PDF

Price: 1 731 SEK
standard ikon

Paper

Price: 2 769,60 SEK
standard ikon pdf + standard ikon

PDF + paper

Show more Show less
Scope
ISO 80601-2-74:2017 applies to the basic safety and essential performance of a humidifier, also hereafter referred to as me equipment, in combination with its accessories, the combination also hereafter referred to as me system.
ISO 80601-2-74:2017 is also applicable to those accessories intended by their manufacturer to be connected to a humidifier where the characteristics of those accessories can affect the basic safety or essential performance of the humidifier.
EXAMPLE 1 Heated breathing tubes (heated-wire breathing tubes) or me equipment intended to control these heated breathing tubes (heated breathing tube controllers).
NOTE 1 Heated breathing tubes and their controllers are me equipment and are subject to the requirements of IEC 60601-1.
NOTE 2 ISO 5367 specifies other safety and performance requirements for breathing tubes.
ISO 80601-2-74:2017 includes requirements for the different medical uses of humidification, such as invasive ventilation, non-invasive ventilation, nasal high-flow therapy, and obstructive sleep apnoea therapy, as well as humidification therapy for tracheostomy patients.
NOTE 3 A humidifier can be integrated into other equipment. When this is the case, the requirements of the other equipment also apply to the humidifier.
EXAMPLE 2 Heated humidifier incorporated into a critical care ventilator where ISO 80601-2-12[12] also applies.
EXAMPLE 3 Heated humidifier incorporated into a homecare ventilator for dependent patients where ISO 80601-2-72[14] also applies.
EXAMPLE 4 Heated humidifier incorporated into sleep apnoea therapy equipment where ISO 80601-2-70[13] also applies.
ISO 80601-2-74:2017 also includes requirements for an active hme (heat and moisture exchanger), me equipment which actively adds heat and moisture to increase the humidity level of the gas delivered from the hme to the patient. This document is not applicable to a passive hme, which returns a portion of the expired moisture and heat of the patient to the resp ...

Subjects

Anaesthetic, respiratory and reanimation equipment (11.040.10)


Buy this standard

Standard Swedish standard · SS-EN ISO 80601-2-74:2020

Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment (ISO 80601-2-74:2017)
Subscribe on standards - Read more Dölj
Price: 1 731 SEK
standard ikon pdf

PDF

Price: 1 731 SEK
standard ikon

Paper

Price: 2 769,60 SEK
standard ikon pdf + standard ikon

PDF + paper

Show more Show less

Product information

Language: English

Written by: SIS - Hälso- och sjukvård

International title:

Article no: STD-80020367

Edition: 1

Approved: 2/26/2020

No of pages: 104

Replaces: SS-EN ISO 8185:2009

Replaced by: SS-EN ISO 80601-2-74:2021