Ventilation for buildings - Test procedures and measurement methods to hand over air conditioning and ventilation systems
Status:
Valid
Buy this standard
StandardSwedish standard
·
SS-EN 12599:2012
Ventilation for buildings - Test procedures and measurement methods to hand over air conditioning and ventilation systems
Subscribe on standards with our subscription service. When you use our service you can be assured the latest editions and easy access.
Read more about SIS Subscriptions
This European Standard specifies checks, test methods and measuring instruments in order to verify the fitness for purpose of the installed systems primarily for handing over which will be partially performed before, during and after handing over. This European Standard enables the choice between simple test methods, when sufficient, and extensive measurements, when necessary. This European Standard applies to mechanically operated ventilation and air conditioning systems as specified in EN 12792 and comprising any of the following: - air terminal devices and units, - air handling units, - air distribution systems (supply, extract, exhaust), - fire protection devices, - automatic control devices. When the system is set, adjusted and balanced measurement methods described in this European Standard apply. This European Standard does not apply to: - heat generating systems and their control, - refrigerating systems and their control, - distribution of heating and cooling medium to the air handling units, - compressed air supplying systems, - water conditioning systems, - central steam generating systems for air humidifying, - electric supply systems. This European Standard applies to ventilation and air conditioning systems designed for the maintenance of comfort conditions in buildings. It is not applicable in the case of systems for the control of industrial or other special process environments. In the latter case, however, it may be referred to if the system technology is similar to that of the above mentioned ventilation and air conditioning systems. This European Standard does not include any requirements concerning the installation contract. However, in order to facilitate the application of this standard, the installation contract should refer to the provisions which are listed in Annex F. The measuring methods in this European Standard can be used in the frame of the energy inspection of air-conditioning systems according to EU Directive 2010/31/EU "Energy ...
Ventilation for buildings - Test procedures and measurement methods to hand over air conditioning and ventilation systems
Subscribe on standards with our subscription service. When you use our service you can be assured the latest editions and easy access.
Read more about SIS Subscriptions