2003-03-10
2010-02-01
This Technical Report gives guidance and other provisions for the training, assessment and approval of fusion operators, with the aim of establishing and maintaining their competency in the constru...
2005-10-10
2008-01-07
Applies only to newly manufactured indoor or outdoor static watt-hour meters of accuracy classes 1 and 2, for the measurement of alternating-current electrical active energy of a frequency in the r...
2000-09-29
2003-01-28
1996-03-13
2004-05-17
Requires that the performance of the earthing arrangements shall satisfy the safety and functional requirements of the electrical installations. Comprises sections of connections to earth; protecti...
1980-01-01
2002-06-14
Amends Clause 546.2: PEN Conductors.
1982-01-01
1998-11-13
2006-09-21
2007-08-14
2008-11-06
Describes how live conductors are protected by one or more devices for automatic interruption of the supply in the event of overload (see clause 433) and short-circuits (see clause 434) except in c...
2001-08-17
2008-08-13
IEC 62055-52:2008(E) specifies a physical layer protocol of the STS for transferring units of credit and other management information between a client (typically a HHU) and a server (an STS-complia...
2008-05-28
IEC 62058-11:2008 specifies the general acceptance inspection methods which apply to newly manufactured electricity meters produced and supplied in lots of 50 and above.
2008-10-08
IEC 62058-21:2008 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated electromechanical meters for active energy (classes 0,5,...
IEC 62058-31:2008 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated static meters for active energy (classes 0,2 S, 0,5 S, 1...
2007-02-22
Specifies hardware and protocol specifications for local systems. Deals with direct local systems, in which the hand held unit is connected to one tariff device only at a time. Connection can be pe...
1996-03-20
Applies to electrical installations such as those of: a)residential premises b)commercial premises c)public premises d)industrial premises e)agricultural and horticultural premises f)prefabricated...
2005-11-29
Describes how protection against electric shock is provided by application of the appropriate measures as specified in: for protection against both direct and indirect contact, for protection again...
2005-12-15
1999-04-28
2004-08-12
Specifies the minimum electrical installation requirements to facilitate the safe design, installation and operation of mobile, temporarily or permanently installed electrical machines and structur...
2000-10-18
Applies to the limitation of temperature rises of connecting interfaces in normal service conditions. This publication has the status of a technical report, type 2.
This technical report is for use as a guide for electrical installations. It explains the relationship between the time/current characteristic of protective devices and wiring, prospective short-c...
This publication has the status of a Technical Report - type 2. Applies to marking for the auxiliary terminals for tariff devices of a.c. electricity meters with induction or static measuring ele...
1995-08-30
This publication has the status of a Technical Report - type 3. It gives examples of performance requirements for local and remote exchange of data between utilities and their customers using two...
1995-11-27
2004-11-01
Describes a 3 layer data exchange architecture used for communication with large industrial and commercial customer's metering equipment (remote reading for billing purpose). The public switched te...
1998-11-16
Describes an architectured application layer used for communication with metering equipment. The associated physical medium and lower layer protocols in a collapsed three-layer model are unspecifie...
1998-11-24
Provides all the information specific to the management DLMS server of the protocols described in IEC 62056-31, 62056-41 and 62056-51. This publication is a Technical Report type 2.