1.1 This test method covers the determination of the resistance of adhered membrane roofing systems to uplift pressure. It applies to roof systems with or without rigid board insulation or base ply, which are either adhered or mechanically fastened, and fully adhered membranes.1.2 This test method is intended to be used as a measure of the uplift resistance of the roofing system. Systems containing cold adhesive shall be in place for the cure time specified by the adhesive manufacturer