1.1 These test methods cover the evaluation of the shear stiffness, shear strength, and ductility of a wall assembly, including applicable shear connections and hold-down connections, under quasi-static cyclic (reversed) load conditions.1.2 Thes
ASTM
Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Walls for Buildings
STD-62666
2007
2007-06-01
13