1.1 This test method uses high performance liquid chromatography (HPLC) to determine nitrogen trichloride levels in liquid chlorine at the 0.1 to 600 µg/g (ppm) range. Solvent samples from chlorine production facilities containing very high concent
ASTM
Standard Test Method for Nitrogen Trichloride in Liquid Chlorine by High Performance Liquid Chromatography (HPLC)
STD-47198
2001
2001-10-10
6