1.1 This test method prescribes the procedure for determining the moisture content of fire-retardant-treated wood and wood-based product samples after exposure to a standard high relative humidity condition of 92 ± 2 % at 27 ± 2°C (81 ± 4°F). 1.2 The text of this test method references